Testing request
The site superintendent identifies the areas, layers or locations requiring compaction testing under the project specification.
Provide adequate notice so attendance can be confirmed.
Requested areas · agreed frequencyREQUESTED FIELD TESTING
Arrange field density testing of placed fill at locations requested by the site superintendent. Results are provided for project-team review, with the scope and attendance agreed before testing.

WHAT LEVEL 2 PROVIDES
The site superintendent identifies the areas, layers or locations requiring compaction testing under the project specification.
Provide adequate notice so attendance can be confirmed.
Requested areas · agreed frequencyField density testing may be completed using the nuclear gauge method under AS 1289.5.8.1 where appropriate to the material and scope.
Safe access and site readiness must be confirmed before attendance.
Field density · moisture measurementField measurements are compared with an applicable laboratory reference density to determine density-ratio results.
The relevant reference test must match the material being assessed.
AS 1289.5.4.1 or AS 1289.5.7.1Test results are issued for review by the site superintendent or project team against the nominated acceptance requirements.
Project acceptance decisions remain with the responsible project party.
Traceable test locations and resultsBOOKING INFORMATION
Send the site and testing details early. Attendance remains subject to confirmation by our team.
Send a testing request ↗FIELD & LABORATORY CONNECTION
Density ratio connects the measured field density to an applicable laboratory reference for the material. Share material details and previous test reports so the correct reference can be reviewed before reporting.
Explore compaction testing ↗AS 1289.5.8.1
AS 1289.5.4.1
AS 1289.5.7.1
The applicable test methods and acceptance criteria are confirmed for each engagement.
COMMON QUESTIONS
No. A result represents the nominated test location and does not certify all fill or provide a statement of compliance for the earthworks.
For Level 2, testing is completed at locations requested by the site superintendent or nominated project representative under the agreed scope.
Tell us when booking. The material and project requirements need to be reviewed, and laboratory compaction testing may be required before a density ratio can be reported.
Contact the laboratory as early as possible with the site, access and testing details. We will confirm attendance based on availability and the agreed scope.